The Four Phases of the Run Cycle on Newer Midmark® M9 & M11 Tabletop Sterilizers
Duration 18:32
Take a detailed look at the four phases of a typical run cycle on the newer style Midmark® M9 & M11 tabletop sterilizers. See and hear what goes on outside of the sterilizer as well as discover what is happening inside the machine during each of the four phases. Plus, find out how to distinguish between the older and newer style Midmark® M9 & M11 tabletop sterilizers. This is an excerpt from the RPI webinar, "A Primer on Tabletop Sterilizer Repair and Maintenance." If you would like to see other topical excerpts from the webinar please see the list below.
The following videos are more topical excerpts from the presentation "A Primer on Tabletop Sterilizer Repair and Maintenance:"
An Introduction to Tabletop Sterilizers (6:15) Learn the history of tabletop sterilizers and the basics of steam sterilization including the three parameters that are necessary for steam sterilization to be effective. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |
|
Saturated vs. Superheated Steam Sterilization (4:35) Learn the difference between saturated and superheated steam and discover why saturated steam is the preferred method for sterilization in tabletop sterilizers. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |
|
Different Styles of Mechanical Bellows (3:19) Discover the three main styles of mechanical bellows and understand the function of a bellows or steam trap in the process of steam sterilization. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |
|
Automatic vs. Manual Sterilizers (11:50) Explore the similarities and differences between automatic and manual tabletop sterilizers. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |
|
The Disassembly of the Midmark® M9 & M11 Fill/Vent Solenoid Valve (7:06) This is a step by step demonstration on how to disassemble the main valve block on newer style Midmark® M9 & M11 Tabletop sterilizers. Learn the different parts of the solenoid block, and see how using the right tools can help make servicing the block quick and easy. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |
|
Troubleshooting Tips for Midmark® M9 & M11 Tabletop Sterilizers (33:34) Learn helpful troubleshooting tips for working with Midmark® M9 & M11 tabletop sterilizers. Find out what to look for when repairing or diagnosing problems with the heating element, PC board, valve assembly, door gasket, door switch, door spring, chamber filters, water lever sensor, temperature sensor, and more. This is an excerpt from the RPI webinar, "A Primer
on Tabletop Sterilizer Repair and Maintenance" that was hosted by TechNation on November 12, 2014. |